A tent's area is the larger of two calculations: the space that tables, stage and dance floor take on the plan, and the number of people times the regulation's per-person factor (1.5 m² for a wedding hall or restaurant). For 200 guests and 15 staff, the plan gives 319.2 m² and the factor 322.5 m². The fire brigade and permit authority say which rule applies to the tent.
The answer to how many square metres a tent should be is the larger of two calculations. The first is the space that tables, stage and dance floor take on the plan. The second is the number of people multiplied by the regulation's per-person area factor. We worked out both for a 200-guest wedding. The same method works for iftars, trade fairs and corporate receptions.
The factors are in the regulation's annex published in the Official Gazette. The authority tells you which rule applies to your tent.
How many square metres per person does the regulation use?
For wedding halls, restaurants, canteens, concerts and multi-purpose halls, 1.5 m² per person is used. This value is in Table Annex-5/A of the Regulation on the Fire Protection of Buildings. The regulation divides the area by the factor to find the number of people who can be in a place at the same time and uses that number to size exits in a fire. It is not a value set to measure seating comfort.
| Area of use | m² / person | Calculated area |
|---|---|---|
| Wedding hall, restaurant, canteen, concert and multi-purpose hall | 1,5 | Net area |
| Dance hall, bar, nightclub: seated part | 1,0 | Net area |
| Dance hall, bar, nightclub: standing part | 0,5 | Net area |
| Exhibition area and studio | 1,5 | Net area |
| Reception and waiting area | 3 | Gross area |
| Supermarket, shop, store | 5 | Gross area |
| Warehouse, storeroom, machine room | 30 | Gross area |
The table's note takes net area for the first four rows and gross area for the others. If the number of people is known in advance, that number is used. But it cannot fall below the value that comes out of the table. The regulation defines occupant load as the total number of people who may be present at any time. By this definition, waiters, musicians and the organising crew can also count.

Summarize this article with AI Open a summary of this article in your preferred assistant
How is the area calculated for a 200-guest wedding?
The example has 200 guests, round tables of 10 and 15 staff. We took the table diameter as 1.8 m. For each table we set aside a 3.6 × 3.6 m square, including the chairs and room to pass. These are our assumptions. Redo the calculation with your own table's real size.
- With guests seated 10 to a table, 20 tables are needed. Each table takes 12.96 m², so the tables occupy 259.2 m².
- A 6 × 4 m stage is 24 m², and a 6 × 6 m dance floor is 36 m².
- The plan total is 259.2 + 24 + 36 = 319.2 m².
- Guests and staff together are 215 people. The factor calculation gives 215 × 1.5 = 322.5 m².
- The two results are close, with the factor calculation slightly ahead. This event needs at least 322.5 m² of net interior area.

Let us pick an example size for this area: a 16 m span and 24 m length make 384 m². Four rows of tables take 14.4 × 18 m. The remaining 6 m strip fits the stage and dance floor side by side and leaves room for entrances and passages. This span is within the 10 to 40 m range in which we build wedding tents. With the same factor, 384 m² corresponds to an exit calculation for 256 people at most. The total of 215 people stays within it.

Items besides tables that enlarge the area
The example made do with tables, a stage and a dance floor. At real events these also enlarge the area:
- The buffet, cake or bar table and the space inside the tent taken by people waiting in front of it.
- Welcome and registration desk, cloakroom.
- Sound and lighting equipment, the orchestra or DJ area.
- Aisles that service staff walk through with trays.
- Kitchen. Tell us from the start whether the food will be prepared inside the tent or in a separate area next to it.
There are no tables at a standing cocktail, so which row applies changes the result a great deal. For a reception and waiting area, 3 m² per person is used; for the standing bar and dance part, 0.5 m². The authority tells you which row your event falls under.
Choosing model and size by area
Once you have the area, you choose the model and size. We build the wedding tent and our other models in the following size ranges. We set the exact size in every project by structural calculation.
| Model | Size range |
|---|---|
| Wedding tent | Span 10-40 m, column-free interior. Sidewall height 3-6 m. |
| Festival tent | Width 10-40 m. Length is modular and extended to suit the event area. |
| Iftar tent | Width 5-15 m, length 10-30 m, height 3-5 m. |
| Fair entertainment tent | Width 3-12 m, height 3-5 m. |
| Shop tent | Width 2-6 m, height 2.5-3.5 m. |
The top of the size range for an iftar tent is 15 × 30 m, that is 450 m². If the 1.5 factor is applied to the dining area, this area corresponds to an exit calculation for 300 people at most. Read this as an upper limit, since tables and service aisles take part of the area. For a larger iftar, look at wide-span models such as the festival tent. We explain how the table layout is drawn for an iftar in our planning article.
For the area you need for a warehouse, sports pitch or animal shelter, you can calculate it on the tent size calculator page. The method in this article is for uses where people gather, such as receptions, iftars and trade fairs. For fair stands in standard sizes, see the folding trade fair tent page.
Is the tent subject to this regulation, and who sets the number of people?
Article 2 of the regulation says it applies to every kind of structure, building and installation in the country and counts temporary constructions and mobile installations as structures. But the text does not mention tents. We also cover the same subject in our article on tarpaulin fire class.
The decision rests with the fire brigade and permit authority of the place where you will put up the tent. Ask the authority in writing which factor the occupant load will be calculated with for this tent and the maximum number of people allowed. Attach the reply to your quote request. The same values are also in the 2007 Official Gazette annex (19.12.2007, no. 26735). The regulation has been amended since then, so read the current text on mevzuat.gov.tr.
Information needed for a quote
We draw the layout in SketchUp and AutoCAD and take the size from that drawing. This information speeds up the drawing:
- Number of guests and estimated number of staff.
- Table type and size, or the seating plan.
- Your wishes for a stage, dance floor, buffet and bar.
- Size and ground type of the site and, if you have it, the authority's written reply about the tent.
- Installation and dismantling dates.
Write to us with these through the contact page. We will work out the size and prepare a quote. All our reception models are on the marquees page, and for free-layout events see our event tent page.